Measurement and Uncertainty Analysis of Propeller Anemometer in Wind Tunnel
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Based on the GB/T24559 marine propeller anemometer test methods and test points, the propeller anemometer was tested in the lowspeed wind tunnel. According to the JJF1059.12012 measurement uncertainty evaluation and expression requirements, seven calibration points of wind speed were tested repeatedly, and the range method was used to evaluate the type A uncertainty. The sources of type B uncertainty in the testing process are analyzed and the type B uncertainty is evaluated. The results show that it is feasible to calibrate the propeller anemometer in the WZ860070E wind tunnel. At the same time, each test point above 2 m/s can meet the three times of the quantitative transmission relationship.

    Reference
    Related
    Cited by
Get Citation

李松奎,贺晓雷,边泽强,刘昕.螺旋桨测风仪风洞测试及不确定度分析[J].气象科技英文版,2021,49(4):524-528.

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:September 22,2020
  • Revised:May 18,2021
  • Adopted:
  • Online: August 23,2021
  • Published: August 31,2021
Article QR Code
You are thevisitors     Copyright:    
Organizer:中国气象局气象探测中心,中国气象科学研究院,北京市气象局,国家卫星气象中心,国家气象信息中心
     Address:北京市海淀区中关村南大街46号       E-mail:100081      Telephone :010-68407256      Fax:010-68407256
Supported by:Beijing E-Tiller Technology Development Co., Ltd.